Wir verwenden Cookies, um für diese Website Funktionen wie z.B. Login, einen Warenkorb oder die Sprachwahl zu ermöglichen. Weiterhin nutzen wir für anonymisierte, statistische Auswertungen der Nutzung Google Analytics, welches Cookies setzt. Mehr Informationen finden Sie in unserer Datenschutzerklärung.
OK, ich bin einverstanden Ich möchte keine Google Analytics-Cookies
Quintessence International
Login:
Benutzername:

Kennwort:

Plattform:

Kennwort vergessen?

Registrieren

Quintessence Int 38 (2007), Nr. 5     27. Apr. 2007
Quintessence Int 38 (2007), Nr. 5  (27.04.2007)

Online Article, Seite 440, PubMed:17568826, Sprache: Englisch


Online Article: Investigation of the wear of prefabricated attachments-An in vitro study of retention forces and fitting tolerances
Bayer, Stefan / Grüner, Manfred / Keilig, Ludger / Hultenschmidt, Robert / Nicolay, Claudia / Bourauel, Christoph / Utz, Karl-Heinz / Stark, Helmut
Objective: To quantify wear processes by measuring the retention force changes and the fitting tolerance at different prefabricated attachment systems to estimate the wear constancy and applicability in clinical practice. Method and Materials: Seven prefabricated attachment systems (Dalbo-Classic, Dalbo-PLUS, Dalbo-Z, Mini-Gerber-PLUS, Stufenexzenter, SphäroLock, and Degussa-Kugelankersystem) with different construction and alloy composition were tested. Twenty samples of each system were subjected to 10,000 insertion-separation cycles in a wear simulator with a periodontium-simulating specimen holder. The simulator was designed to record the force needed to insert and to separate the attachment and the distance moved during the insertion and separation cycles.
Results: All types of anchors showed wear that led to a loss or to an increase in retention force at the beginning of the wear simulation. Anchors with a plastic retention insert showed the slightest changes in retention force. The wear does not have an effect on the fitting tolerance.
Conclusion: Anchor systems that possess an adjustable matrix should be preferred. They allow decreasing or increasing the retention force of an anchor if this force is changed by wear. There is no risk of a loss of support if forces in occlusal direction are exerted because there is no clinically relevant change in the fitting tolerance.

Schlagwörter: anchors, fitting tolerance, overdentures, prefabricated attachments, retention force changes, wear
Volltext (keine Berechtigung) einzeln als PDF kaufen (20.00 €)Endnote-Export